Standardized |
- S 250 Shelter

- S 280 CG Shelter

- NATO STD ACE III Shelter

- ISO 20 Feet Shelter

S-250/G Shelters are made to comply with MIL specification MIL S-55541 and are general purpose, light weight, all weather shelters housing communication equipment. Due to their size and light weight they are easily transportable by any high mobility wheeled vehicles of 1.25 to 2 Ton capacity both commercial and Military. For the same reason they are also easy to transport by helicopters, cargo air craft, rail and ship.
|

S-250 |
Shelter panels are made using controlled thermal pressure bonding technology, which is extensively used by leading shelter manufacturers in US and Europe. Panel wall skins are of single sheet, joint less, special grade Alluminium alloy. These sheets sandwich solid polyurethane foam blocks interspersed with welded Alluminium alloy grid structure. All the six walls are joined and assembled using specially extruded Alluminium profiles, corner angles and rivets to make an excellent and strong shelter capable of rugged and rapid handling and employment by the field forces in all weather and all terrain conditions. To add to the hoop strength all the reinforcement beams are engineered and aligned in all the panels to form a continuous loop to give the structure good strength to weight ratio and the ability to withstand the prescribed roof loads and drop strengths.
|
Mechanical Detail:
|
|
External Dimensions |
: |
87” L x 79” W x70” H 2210 mm (L) x 2007 mm (W) x 1778 mm (H) |
|
Internal Dimensions |
: |
78” L x75” W x 64“ H1981 mm (L) x 1905 mm (W) x 1626 mm (H) |
|
Heat transfer coefficient |
: |
U-Factor-0.28 BTU/hr/sq.ft/F |
|
Weight |
: |
375 Kgs Max. |
|
Payload |
: |
855 Kgs |
|
Water tightness |
: |
for a fording depth of 762 mm |
|
Operating temp |
: |
-20ºC to +55ºC |
|
Storage temp |
: |
-40ºC to +70ºC |
|
Door Lock device |
: |
Three point roller cam latching mechanism |
|
Roof load |
: |
366.08 Kg / Sq.Mtr. |
|
Skids |
: |
Two longitudinal Skids |
|
Floor load |
: |
1134 Kgs over 0.278 Sq.Mts |
|
Roof access |
: |
Recessed folding steps |
|
|
|
|
|
Technical Detail:
|
|
|
Detail View |
Modified View |
|
|
|
|
|
|
Speck manufactures S-280/C/G Shelters which comply with MIL STD 55286E. Used by Defence forces across the world, these shelters house electronic equipment for battle field mobile applications, facilitating rapid movement, quick deployment and instant operation
|
 S-280 |
|
Panels of S-280 /G shelters are manufactured by “controlled thermal pressure bonding technology” adopted and extensively used by leading shelter manufacturers across US and Europe. The panel wall skins are engineered to make an excellent and strong shelter, capable of rugged & rapid handling and deployment by field forces in all weather and terrain conditions. Some of their unique features include single sheeting, joint less and use of special grade Alluminium alloy.
These sheets sandwich solid polyurethane foam blocks interspersed with welded Alluminium alloy grid structure. All the six walls are assembled using specially extruded Alluminium profiles, corner angles and rivets. To add to the hoop strength, all the reinforcement beams are engineered and aligned in all the panels, to form a continuous loop to give the structure a very good strength to weight ratio and the ability to withstand the prescribed roof loads and drop strengths.
|
Mechanical Detail:
|
|
|
|
|
External Dimensions |
: |
147” L x 87” W x86 3/8” H 3748 mm (L) x 2196 mm (W) x 2184 mm (H) |
|
Internal Dimensions |
: |
138” L x 81 1/2” W x 74 1/2“ H 3505 mm (L) x 2070 mm (W) x 1959 mm (H) |
|
Heat transfer coefficient |
: |
U-Factor-0.28 BTU/hr/sq.ft/F |
|
Payload |
: |
2250 Kgs |
|
Water tightness |
: |
for a fording depth of 762 mm |
|
RFI Shielding |
: |
60 db when measured as per MIL-SD-285 |
|
Operating temp |
: |
-20ºC to +55ºC |
|
Storage temp |
: |
-40ºC to +70ºC |
|
Door Lock device |
: |
Three point roller cam latching mechanism |
|
Roof load |
: |
366.08 Kg / Sq.Mtr. |
|
Skids |
: |
Three full length Skids |
|
Floor load |
: |
1134 Kgs over 0.278 Sq.Mts |
|
Roof access |
: |
Recessed folding steps |
|
Lifting eyes |
: |
Four(4) eyes with 3” inside clearance and 6532 kgs |
|
|
|
tensile load per corner in all directions |
|
Towing eyes |
: |
Four(4) eyes with 3” inside clearance and 6532 kgs |
|
|
|
tensile load per corner in all directions |
|
|
|
|
|
|
|
|
Technical Detail:
|
|
|
|
|
|
Detail View |
Modified View |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
NATO ACE III Shelters are made to comply with Allied Command Europe’s Standard specification 6516/SHCPR/86. These are general purpose, light weight, all weather shelters for housing communication and other transportable electronic equipment.
|

NATO STD ACE III Shelter |
Panels of NATO ACE III shelters are manufactured by “controlled thermal pressure bonding technology” adopted and extensively used by leading shelter manufacturers across US and Europe. The panel wall skins are engineered to make an excellent and strong shelter, capable of rugged & rapid handling and deployment by field forces in all weather and terrain conditions. Some of their unique features include single sheeting, joint less and use of special grade Alluminium alloy.
These sheets sandwich solid polyurethane foam blocks interspersed with welded Alluminium alloy grid structure. All the six walls are assembled using specially extruded Alluminium profiles, corner angles and rivets. To add to the hoop strength, all the reinforcement beams are engineered and aligned in all the panels, to form a continuous loop to give the structure a very good strength to weight ratio and the ability to withstand the prescribed roof loads and drop strengths.
|
Mechanical Detail:
|
|
External Dimensions |
: |
5000 mm (L) x 2200 mm (W) x 2075 mm (H) |
|
Internal Dimensions |
: |
4835 mm (L) x 2034 mm (W) x 1884 mm (H) |
|
Heat transfer coefficient |
: |
U-Factor-0.28 BTU/hr/sq.ft/F |
|
Payload |
: |
2250 Kgs standard configuration. Adaptable for higher payloads |
|
RFI Shielding |
: |
60 db when measured as per MIL-STD-285 |
|
Water tightness |
: |
Completely watertight tested for a fording |
|
|
|
depth of 500 mm and to simulated rainfall |
|
Operating temp |
: |
-20ºC to +55ºC |
|
Storage temp |
: |
-40ºC to +70ºC |
|
Door lock |
: |
Three point roller cam latching mechanism |
|
Roof load |
: |
3660 N/m² |
|
Skids |
: |
Three full length Skids |
|
Floor load |
: |
10 KN over any 0.25/ m² area |
|
Roof access |
: |
Recessed folding steps |
|
Corners |
: |
All the 8 corners equipped with ISO corners |
|
|
|
complying ISO 1161-1976 |
|
Technical Detail:
|
|
|
|
|
|
Speck manufactures what are commonly known as “ISO 20 feet shelters”(8’ X 8’ X 20’ in dimensions), which comply with MIL STD M-81957 (AS), and are used for housing electronics and communication equipment for tactical purposes and with applications also as maintenance and repair facilities.
|

ISO 20 Feet Shelters |
Like all other MIL STD Shelters these can also be integrated with environmental control units, air ducts, generators, lights, racks, antennae and made suitable for operations by combat units in extreme weather and geographical conditions. EMI shielding levels of more than 60 dB have been achieved. ISO 20 feet shelter will have a bottom M.S. frame with forklift pockets as per ISO:1496-1 and steel corner angles and ISO corners as per ISO-1161.
These sheets sandwich solid polyurethane foam blocks interspersed with welded Alluminium alloy grid structure. All the six walls are assembled using specially extruded Alluminium profiles, corner angles and rivets. To add to the hoop strength, all the reinforcement beams are engineered and aligned in all the panels, to form a continuous loop to give the structure a very good strength to weight ratio and the ability to withstand the prescribed roof loads and drop strengths.
|
Mechanical Detail:
|
|
External Dimensions |
: |
96 in. (H) , 96 in. (W) , 238-1/2 in. (L) |
|
|
|
2438.4 mm , 2438.4 mm , 6058 mm , (L) |
|
Internal Dimensions |
: |
84-5/16 in. (H),89-13/16 in. (W), 232-5/16 in (L) |
|
|
|
2141.5 mm, 2281.3 mm, 5901.5 mm |
|
Heat transfer coefficient |
: |
U-Factor-0.28 BTU/hr/sq.ft/F |
|
Payload |
: |
7076 Kgs |
|
RFI Shielding |
: |
> 60 db when measured as per MIL-STD-285 |
|
Operating temp |
: |
-20ºC to +55ºC |
|
Storage temp |
: |
-40ºC to +70ºC |
|
Door lock |
: |
Three point roller cam latching mechanism |
|
Roof load |
: |
366.08 Kg / Sq.Mtr. |
|
Skids |
: |
Three full length Skids |
|
Floor load |
: |
1134 Kgs over 0.278 Sq.Mts. |
|
Roof access |
: |
Recessed folding steps |
|
Service Life |
: |
15 Years |
|
Storage |
: |
20 Years |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|